TM 55-1945-205-24-4
0099 00 1
0099 00
UNIT LEVEL MAINTENANCE
FLOATING CAUSEWAY
HEATING AND AIR CONDITIONING SYSTEM VENT AIR FILTER
REMOVAL, CLEANING, INSPECTION AND INSTALLATION
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Item 53, WP 0253 00)
Gloves, Chemical (Item 14, WP 0253 00)
Goggles, Industrial (Chipping, Chemical) (Item 17, WP 0253 00)
Apron, Utility (Item 1, WP 0253 00)
Brush, Stencil (Soft Bristle) (Item 4, WP 0253 00)
Materials/Parts
Cleaner (Item 7, WP 0252 00)
Personnel Required
Engineer 88L
REMOVE HEATING AND AIR CONDITIONING SYSTEM VENT AIR FILTER
1.
Pull vent door (1) open.
2.
Remove vent air filter (2) by gently pushing on the filter slot.
CLEAN HEATING AND AIR CONDITIONING SYSTEM VENT AIR FILTER
WARNING
1.
Clean air vent filter (2) using a soft bristle brush and cleaner.
2
1