TM 55-1945-205-24-4
0144 00 1
0144 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER CONTROL PANEL HOUR METER
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Item 53, WP 0253 00)
Gloves, Mens and Womens (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Materials/Parts
Hour Meter
(33968)
PN 36841245
Personnel Required
Engineer 88L
Equipment Condition
Light Tower Battery Negative Lead Terminal Removed. (WP 0131 00)
REMOVE LIGHT TOWER CONTROL PANEL HOUR METER
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during FC operations and maintenance. Failure to observe these precautions could
result in serious injury or death.
1.
Remove nine hex head bolts (1) from control panel (2).