TM 55-1945-205-24-4
0019 00 1
0019 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
ENGINE BATTERY DISCHARGED
SYMPTOM
Light tower has no DC power.
MALFUNCTION
Battery electrolyte insufficient.
CORRECTIVE ACTION
Replenish distilled water and charge. (WP 0138 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Fan belt slips.
CORRECTIVE ACTION
Replace fan belt. (WP 0180 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Alternator
defective.
CORRECTIVE ACTION
Replace
alternator
. (WP 0135 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)