TM 55-1945-205-24-4
0017 00 1
0017 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
ENGINE IS DIFFICULT TO START
SYMPTOM
Engine is difficult to start.
MALFUNCTION
Air in the fuel system.
CORRECTIVE ACTION
Inspect for loose couplings, cap nuts, screws and fittings and repair as necessary.
MALFUNCTION
Engine does not have proper quantity of oil installed.
CORRECTIVE ACTION
Check oil quantity and add oil as required. (WP 0162 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Engine fuel filter(s) are contaminated with water or other debris.
CORRECTIVE ACTION
Drain engine fuel filter bowl. (WP 0164 00)
Replace engine fuel filter element. (WP 0162 00)
Replace in line fuel filter. (WP 0168 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Battery is not properly charged.