TM 5-1940-322-24
0044 00
ACCESS PANEL AND HINGES MAINTENANCE (Contd)
NOTE
If rivets are present, drill out and replace with screws, washers,
and locknuts. Refer to TM 5-1940-322-24P for all mounting
hardware.
REMOVAL
NOTE
Perform step 1 if rivets are present. Perform step 2 if locknuts,
washers, and screws are present.
1.
Drill out six rivets (6) from hinges (5) and bulkhead (2). Discard rivets (6).
2.
Support access panel (1) and remove six locknuts (3), twelve washers (4), and six screws (7) from
access panel (1) and bulkhead (2). Remove access panel (1) from bulkhead (2). Discard locknuts (3).
3.
Remove six locknuts (3), twelve washers (4), six screws (7), and two hinges (5) from access panel (1).
Discard locknuts (3).
CLEANING AND INSPECTION
1. For general cleaning and inspection instructions, refer to WP 0013 00.
2.
Inspect threads on bolt bracket (8) for damage. If damaged, remove four locknuts (10), four
washers (9), four screws (12), and two bolt brackets (8) from access panel opening (11). Discard
locknuts (10).
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
3.
Check for missing or damaged rubber seal (13). If missing or damaged, clean area with Skysol 100, dry
with cloth, and replace rubber seal (13).
INSTALLATION
1. Apply light coat of adhesive on inside edges of access panel (1).
2.
Install new rubber seal (13) around inside edges of access panel (1).
3.
If bolt brackets (8) where removed, install two bolt brackets (8) on access panel opening (11) with four
screws (12), four washers (9), and four new locknuts (10).
4.
Install two hinges (5) on access panel (1) with twelve washers (4), six screws (7), and six new
locknuts (3).
5.
Position access panel (1) with hinges (5) on bulkhead (2).
6.
Secure two hinges (5) on bulkhead (2) with six screws (7), twelve washers (4), and new locknuts (3).
7.