TM 5-1940-322-24
0045 00
STOWAGE COMPARTMENT DOOR, MAP LOCKER DOOR, AND HINGES MAINTENANCE (Contd)
NOTE
The stowage compartment door, map locker door, and hinges are
replaced the same way. This procedure covers the stowage
compartment door.
If rivets are present, drill out and replace with screws, washers,
and locknuts. Refer to TM 5-1940-322-24P for all mounting
hardware.
REMOVAL
1.
Drill out rivets (8) or remove six locknuts (5), twelve washers (6), six screws (9), and door (1) from
bulkhead (4). Discard locknuts (5).
2.
Drill out rivets (8) or remove six locknuts (5), twelve washers (6), six screws (9), and hinges (7) from
door (1). Discard locknuts (5).
INSPECTION
1.
2.
Latch (10) and hasp (3) are welded to door (1) and bulkhead (4). Replace latch (10) or hasp (3) if
damaged. Refer TC 9-237 for welding repair.
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
3.
Inspect rubber seal (2) for damage. If missing or damaged, clean area with Skysol 100 and replace
rubber seal (2).
INSTALLATION
1.
Apply coat of adhesive on edges of door (1).
2.
Install new seal (2) on door (1).
3.
Install two hinges (7) on door (1) with six screws (9), twelve washers (6), and six new locknuts (5).
4.
Install door (1) and hinges (7) on bulkhead (4) with six screws (9), twelve washers (6), and six new
locknuts (5).
0045 00-2