TM 5-2090-200-12&P
(2)
Remove pins (8-12 and 42) and remove cables (7, 11 and 45).
(3)
Refer to figure 4-2 and remove cable lashing assemblies.
b. Cleaning, inspection and repair.
(1)
Inspect all cables for wear, breaks, and damage. Inspect for missing, worn or damaged
hardware.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 100° F. - 1380 F. (38° C. - 59° C.).
(2)
Clean cables and hardware with dry cleaning solvent (Fed. Spec P-D-680).
(3)
Replace any damaged or worn cables. Replace missing or damaged hardware.
c.
Installation.
(1)
Install cables (1, 7, 11 and 45) and secure with pins (2, 8, 12 and 42).
(2)
Refer to figure 4-2 and install cable lashing assemblies.
Key to figure 4-1
1
Tie down cable
24
Access cover
2
Pin
25
Capscrew
3
Wire rope
26
Lockwasher
4
Sleeve
27
Washer
5
Shackle
28
Shackle
6
Hook
29
Shackle
7
Tie down cable
30
Pin
8
Pin
31
Wire rope
9
Wire rope
32
Sleeve
10
Sleeve
33
Cradle stanchion
11
Tie down cable
34
Boat guide stanchion
12
Pin
35
Pin
13
Wire rope
36
Wire rope
14
Sleeve
37
Sleeve
15
Pin
38
Nut
16
Washer
39
Nut
17
Cotter pin
40
Shackle
18
Shackle
41
Rope
19
Screw pin shackle
42
Pin
20
Lashing cable
43
Wire rope
21
Lashing cable
44
Sleeve
22
Identification plate
45
Cable
23
Rivet
Change 2
4-4