P r e v e n t i v e Maintenance Checks and Services for M60A1 AVLB Hull-
Continued
Location
Interval
Item
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable if:
33
Semiannual
Dust Detector
Filter Strip (Left
and Right Sides)
(If Equipped)
NOTE
Service dust detector filter strip quarterly, or after 750 miles of
operation, or when dust detector indicates ingestion of foreign matter.
Open top deck grille doors
(TM 5-5420-202-10).
Remove dust and dirt from filter
strip cover and compressor housing.
Loosen three screws securing filter
strip cover to compressor housing.
Remove cover.
Remove filter strip with retainer
from filter strip cover
(page 7-130.11).
Clean cover and mounting face of
compressor housing.
Inspect compressor housing chamber
for contamination. Clean chamber as
required.
3-42