AIR CLEANER INTAKE ELBOW REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
Position new gasket (A) onto studs of air cleaner.
2.
Install elbow (B) onto studs of air cleaner.
3.
Install 10 self-locking nuts (C) onto studs to secure elbow (B) to air cleaner.
4.
Using 9/16 inch socket, universal joint, extension, and 9/16 inch wrench, as necessary,
tighten 10 nuts (C).
5.
Install hose (D) onto elbow (B).
6.
Slide clamp (E) up over hose (D) and onto elbow (B).
7.
Using 3/8 inch wrench, tighten clamp nut (F) to secure clamp (E).
8.
End of Task