FUEL-WATER SEPARATOR OPERATIONAL TESTS - Continued
FUEL-WATER SEPARATOR OPERATIONAL TESTS - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  429    430    431    432    433  434  435    436    437    438    439  
img
TM 5-5420-202-20-2
FUEL-WATER SEPARATOR OPERATIONAL TESTS (Sheet 10 of 11)
Sequential Drain Test (Sheet 3 of 4)
11.
Remove tip of lower sensor (J) from water in metal container (K) before 18 3 seconds
have gone by from time of putting it in and check if fluid stops draining from solenoid
drain valve drain tube (N).
12.
If fluid does not start draining
(step 9), does not keep draining
(step 10), or does not stop draining
(step 11), refer to troubleshooting
procedures (page 4-247).
13.
Disconnect lead at contact A (E) and at
positive (+) terminal of power source (P).
14.
Disconnect lead at contact B (Q) and at
negative (-) terminal of power source (P).
15.
Disconnect jumper wire from metal
container (K) and negative (-) terminal
of power source (P).
16.
Remove metal container (K) with water
and fuel from under solenoid drain valve
drain tube (N).
17.
Using pliers, connect engine electrical harness
connector (R) to fuel-water separator control
box (F) by turning clockwise.
Go on to Sheet 11