FIRE EXTINGUISHER RELAY AND MASTER RELAY CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 2)
INTERCONNECTING BOX ASSEMBLY REPLACEMENT (Sheet 1 of 1)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  141    142    143    144    145  146  147    148    149    150    151  
img
TM 5-5420-202-20-3
FIRE EXTINGUISHER RELAY AND MASTER RELAY CIRCUIT BREAKER REPLACEMENT
(Sheet 2 of 2)
INSTALLATION:
1.
Place circuit breaker (A) in position
in launcher.
2.
Using screwdriver, install two screws
(B) and lockwashers (C) securing
circuit breaker (A) to vehicle.
3.
Apply silicone compound to two
electrical connectors (D).
4.
Install two electrical connectors (D) in circuit breaker (A) by
pushing in.
5.
Install access plate (page 17-9).
TA249083