HEU MAIN POWER WIRING HARNESS DISCONNECT - Continued
HEU MAIN POWER WIRING HARNESS DISCONNECT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  386    387    388    389    390  391  392    393    394    395    396  
img
TM 5-5420-202-20-3
MAIN POWER WIRING HARNESS DISCONNECT (Sheet 5 of 7)
INSTALLATION:
1. Place main power wiring harness (D) into vehicle.
2. Route main power wiring harness from right side of vehicle along voltage regulator to upright
support (V) and connect main power wiring harness lead (W) (CKT 509B) to dust detector
wiring harness (X).
3. Route main power wiring harness (D) (CKT 49) from right side of vehicle to slave receptacle
(U) located in front of driver.
Change 7
10-296.85
Go on to sheet 6.