HEU MAIN POWER WIRING HARNESS DISCONNECT - Continued
HEU MAIN POWER WIRING HARNESS DISCONNECT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  387    388    389    390    391  392  393    394    395    396    397  
img
.
TM 5-5420-202-20-3
MAIN POWER WIRING HARNESS DISCONNECT (Sheet 6 of 7)
4.
Using 9/16 inch wrench install screw (S) lock washer (T) and main power wiring harness (D) (CKT 49) onto slave
receptacle (U).
5.
Using 7/16 inch socket and ratchet, and 7/16 inch wrench install slave receptacle cover (R) 2 screws (N) washers (P)
and nuts (Q) onto slave receptacle (U).
6.
Using 7/16 inch socket and ratchet install 4 screws (K) washer (L) and 4 clamps securing harness from right side of
vehicle to vehicle slave receptacle.
7.
Using a 9/16 inch wrench install 3 nuts (G ) and screws (H) thru positive battery terminals (J) and main power
wiring harness (D) (CKT 81).
Go on to sheet 7.
10-296.86
Change 7