FIXED FIRE EXTINGUISHER INTERIOR RELEASE MECHANISM CONTROL ASSEMBLY REPLACEMENT - Continued
FIXED FIRE EXTINGUISHER INTERIOR RELEASE MECHANISM CONTROL ASSEMBLY REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -4 Page Navigation
  145    146    147    148    149  150  151    152    153    154    155  
img
. .
TM 5-5420-202-20-4
FIXED FIRE EXTINGUISHER INTERIOR RELEASE MECHANISM CONTROL ASSEMBLY
REPLACEMENT (Sheet 5 of 7)
INSTALLATION:
1.
Thread cables (A) through two control
assemblies (B).
2.
Using fingers, place two control assem-
blies (B) in position on release mechanism
(C), making sure two cables (A) are
threaded through holes in release mech-
anism (C).
3.
Using 3/8 inch wrench on flats (D) of two control assemblies (B), tighten two control
assemblies (B) into place on release mechanism (C).
GO on to Sheet 6