TM 5-5420-203-14
c . Assembly of the MLC 70 Bridge - CONT
(25) Installation of Cable Retainer.
WARNING
Broken cable strands can cause injury. Wear protective gloves when handling cables.
(a) Lay scissoring cables (1) in
grooves (2) of quadrant (3).
Ensure cable strands twist as
previously instructed.
(b) Position cable retainer (4)
between slots (5) located on top of
quadrant (3).
(c) Insert locking retainer pins (6)
pinning cable retainer (4) in
position.
(d) Insert one retainer (7) in each
locking retainer pin (6) as shown.
Retainers (7) are placed through
both ends of retainer pins (6).
Flare ends of retainer, if
necessary, to reduce the chance of
loss.
(e) Insert two pin retainers (8) in
opposite ends of two locking
retainer pins (6) if previously
removed.
2-54 Change 2