TM 5-5420-203-14
c. Assembly of the MLC 70 Bridge - CONT
(22) Bridge Sections Flexible Hydraulic Hose Connections and Brackets.
NOTE
The two hoses mounted on the diaphragm of the near-shore end must cross. Hoses for
the far-shore do not cross.
(a) Install one 3 ft. 4 in. flexible hydraulic hose (1) to the fitting located on the near-shore
female section (2).
(b) Remove the quick-release plug end (3) from pipe nipple (4).
(c) Insert the quick-release plug end
(3) of the flexible hydraulic hose
(1) through the opposite quick-
disconnect bracket (5) located on
the diaphragm (6). Thread
quick-release plug end (3) on
pipe nipple (4). Place protective
dust cap (7) in holder (8).
(d) Install one 3 ft. 4 in. flexible
hydraulic hose (1) to the fitting
located on the far-shore female
ramp section (2).
(e) Remove the quick-release plug
end (3) from pipe nipple (4).
(f) Insert the quick-release plug end
(3) of the flexible hydraulic hose
(1) through the quick-disconnect
bracket (5) located on the
diaphragm (6). Thread quick-
release plug end (3) on pipe
nipple (4). Place protective dust
cap (7) in holder (8).
Change 2 2-51