TM 5-5420-203-14
CENTER SECTION MISCELLANEOUS COMPONENTS REPLACEMENT (Sheet 2 of 3)
d. Remove two nuts (15) and two lock washers (16) from two screws (17) holding pipe anchor
clamp (18) to angle bracket (19). Discard lock washers.
e. Remove two nuts (20) and two lock washers (21) from two screws (22). Remove angle bracket
(19). Remove two flat washers (23) and two screws (22) from center section (5). Discard lock
washers.
f. Remove two nuts (24) and two lock washers (25) from two screws (26). Remove angle bracket
(27). Remove two flat washers (28) and two screws (26) from center section (5).Discard lock
washers.
g. Remove nut (29) and lock washer (30) from screw (31). Remove spring tension clip (32), flat
washer (33), and screw (31) from center section (5). Discard lock washer.
h. Remove two nuts (34) and two lock washers (35) from two screws (36). Remove angle bracket
(37). Remove two flat washers (38) and two screws (36) from center section (5). Discard lock
washers.
i. Remove two nuts (39), two lock washers (40), two flat washers (41), and two screws (42)
securing pipe flange (43) to center section (5). Remove pipe flange (43) from center section (5).
Discard lock washers.
INSTALLATION
INSTALL CENTER SECTION MISCELLANEOUS COMPONENTS.
a. Position male hose guide (4) in position on center section (5). Secure by placing screw (3) through
guide (4) and section (5). Install new lock washer (2) on screw (3) and secure with nut (1).
Tighten securely.
b. Position spring retainer (8) on center section (5). Place flat washer (9) on screw (10) and through
retainer (8) and center section (5). Install new lock washer (7) and nut (6) on screw (10). Tighten
nut (6).
c. Position female flexible hose guide (14) on center section (5). Install screw (13) through mounting
bracket of hose guide and mounting hole on section (5). Install new lock washer (12) and nut (11)
on screw (13). Tighten nut (11).
d. Place two flat washers (23) on two screws (22). Position angle bracket (19) on center section (5).
Install two screws (22) through angle bracket and center section (5). Install two new lock washers
(21) and two nuts (20) on two screws (22). Tighten nuts (20).
3-75