b. Repair.(figure 4-74)WARNINGDry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and property.Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash pointof solvent is 100-138 °F (38-60 °C).(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)Clean all items with dry cleaning solvent, and dry thoroughly.Inspect all components for wear, hole elongation, or damage. Replace if damaged.Inspect link (2) and replace if bent, cracked, pin holes are excessively worn or link (2) is other wise damaged.Inspect link (3) and replace if bent, or pin holes are excessively worn or link (3) is otherwisedamaged.inspect lever (4) and bushing (5). Replace bushing (5) if cracked, or excessively worn. Replace lever if bent,cracked, or otherwise damaged.Inspect hand control shaft (6) and replace if bent, excessively worn, or otherwise damaged.Inspect pins (7) and replace if excessively worn or otherwise damaged.Inspect spacer (8) and replace if cracked, excessively worn, or otherwise damaged.Inspect control assembly (9) and replace if bent, excessively worn, or otherwise damaged.Inspect all remaining items and replace all items that are worn or otherwise damaged.4-210TM 5-5420-209-12