TM 5-5420-209-34
2-5. Direct Support Troubleshooting Procedures. Table 2-1 lists the common malfunctions
that may be found during operation. Refer to Symptom Index to locate the troubleshooting procedures for
the malfunction. This manual cannot list all malfunctions that may occur, nor all tests or inspections and cor-
rective actions. If a malfunction is not corrected by listed corrective actions, notify your supervisor.
SYMPTOM INDEX
Symptom
Page
Cable Tensioner Assembly Inoperative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Tensioner Motor Inoperative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Ramp Bay Bow Pontons Leak@ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Ramp Bay Roadway Pontons Leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Interior Bay Bow Pontons Leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Interior Bay Roadway Pontons Leaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Table 2-1. Direct Support Troubleshooting Procedures.
Malfunction
Test or Inspection
Corrective Action
1. CABLE TENSIONER ASSEMBLY INOPERATIVE.
Inspect cable tensioner assembly for damage.
Repair cable tensioner assembly (para. 2-8).
2. TENSlONER MOTOR INOPERATIVE.
Inspect motor for damage or missing components.
Replace tensioner motor (para. 2-9).
3. RAMP BAY BOW PONTONS LEAKING.
Inspect for structural damage, cracks, broken welds or holes through skin.
Repair bow ponton (para. 2-11).
4. RAMP BAY ROADWAY PONTONS LEAKING.
Inspect for structural damage, cracks, broken welds or holes through skin.
Repair roadway pontons (para. 2-12).
2 -2