2-8. Cable Tensioner Assembly.This task covers:RepairINITIAL SETUPToolsGeneral Mechanic’s Tool Kit(NSN 5180-00-177-7033)Materials/PartsCompound, Sealing (Item 1, Appendix B)Solvent, Dry Cleaning (Item 2, Appendix B)Rags, Wiping (Item 5, Appendix B)Equipment Condition:Cable Tensioner Assembly removed(TM 5-5420-209-12).a. Repair. (figure 2-1)WARNINGDry cleaning solvent, PD-680, used to dean parts is potentially dangerous to personnel andproperty. Avoid repeated and prolonged skin contact. Do not use near open flame or exces-sive heat. Flash point of solvent is 100 ‘F-138‘F (380 C-600 C).CAUTIONThoroughly dean cable tensioner with solvent prior to disassembly to prevent contaminationand equipment damage.NOTEScrews are installed with sealing compound and may require heating for removal.(1) Remove locknut(1), nut (2), spring washers (3) and washers(4).(2) Remove nut (5), lockwasher (6), bolt(7), shaft(8), and lube fitting (9).2 - 4TM 5-5420-209-34