2-8. Cable Tensioner Assembly. - ContinuedNOTEMask all external and internal threads, grooves and ports prior to surface treatment.(24) Remove minor nicks and scratches from exterior surfaces area and treat and paint repairedareas in accordance with MIL-T-704, Type B.NOTEScrews which have been heated for removal must be replaced. Secure all screws exceptmotor mounting hardware with sealing compound.(25) Install bearing (44), bearing (43), sealing ring (42), bearing (41), and retaining ring (40) inplanetary flange (21).(26) Install drive shaft (39) into planetary flange (21) and secure with washer (38) and screw (37).(27) Install bearing (47) and radial sealing ring (46) into housing (12).(28) Install internal geared wheel (45) and bearing (44) into housing (12).(29) Install planetary flange (21) into housing (12).(30) Install seal (34) and plug (33) in cover (36) and secure cover to housing (12) with eight screws(35).(31) Install tooth wheel (31) on rope pulley (30) and secure with six screws (32).(32) Install rope pulley (30) and bearings in arm (26) using pin (28).(33) Install pin (27) into housing (12) and slide arm (26) on pin (27) and secure with retaining ring(25).(34) Install tooth wheel (24) on rope pulley (20) and secure with six screws (23).(35) Install fitting key(22) in planetery flange (21) and install rope pulley (20) on phnetary flange( 21)and secure with retaining ring (19).(36) Install flange (17) and secure with two screws (18).(37) Install key (16) and motor (15) and secure with two screws (13) and washers (14).(38) Install plug (10) and seal (11).2-8TM 5-5420-209-34