ARMY TM 5-5420-212-10-1
MARINE CORPS TM 08676A-10/1-1
(3)
Hold shoot bolt (3), then unscrew and remove handle (1) by turning handle counterclockwise.
(4)
Remove shoot bolt (3) from housing (4).
b.
Service/Repair
(1)
Inspect shoot bolt and handle for burrs, cracks and breaks.
(2)
Remove burrs with flat file.
(3)
Clean shoot bolt and handle with an oil soaked cloth.
(4)
Wipe dry with a clean, dry cloth.
(5)
Replace shoot bolt if cracked, bent or broken.
c.
Installation
(1)
Insert shoot bolt (3) into housing (4), until handle hole is inside of housing.
(2)
Ensure threads of handle are coated with thread locking compound, hold shoot bolt in place and screw
in the handle (1).
(3)
Tighten the handle with small diameter bar, where possible, or pliers/visegrips.
8-29