TM 5-5420-226-20-2
AIR CLEANER lNTAKE ELBOW REPLACEMENT (Sheet 2 0f 3)
REMOVAL:
Using 3/8 inch wrench, loosen clamp nut (A).
1.
Slide clamp (B) down over hose (C).
2.
3. Disconnect hose (C) from elbow (D).
Using 9/16 inch socket, universal joint, and 9/16 inch wrench, as necessary, remove 10
4.
nuts (E) securing elbow (D).
5. Using pry bar, pry elbow (D) away fro m air cleaner.
6. Remove elbow (D) off studs (F) of air cleaner.
7. Remove and discard gasket (G) from studs of air cleaner.
TA107678
Go on to Sheet 3
7-73