AIR CLEANER TURBOCHARGER ELBOW REPLACEMENT - Continued
AIR CLEANER BLOWER FAN POWER LEAD REPLACEMENT - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  256    257    258    259    260  261  262    263    264    265    266  
img
. . . .
TM 5-5420-226-20-2
AIR CLEANER BLOWER FAN POWER LEAD REPLACEMENT (Sheet 1 of 3)
Slip joint pliers
TOOLS:
REFERENCE: TM 5-5420-226-10
Open top grille doors (TM 5-5420-226-10)
PRELIMINARY PROCEDURES:
Remove blower fan hose (page 7-103)
NOTE
Removal of left or right blower
fan power lead is the same. Left
side shown.
REMOVAL:
1.
Disconnect electrical connector (A).
Push shell (B) back away from contact (C).
2.
Using slip joint pliers, remove washer
3.
(D) from contact (C).
Remove shell (B).
4.
TA107683
Go on to Sheet 2