Master control Panel Wiring Harness Replacement (Sheet 6 of 7)
Connect two leads (circuit 14) to starter switch (L).
5.
6. Connect electrical connector (circuit 459) to master battery switch (M).
Connect lead (circuit 37) to bilge pump and utility outlet circuit breaker (N).
7.
Connect electrical connector (circuit 400) to master heater switch connector (P).
8.
Connect lead (circuit 27) to gage circuit breaker (Q).
9.
10. Connect leads (circuit 14) (R).
TA168757
Go on to Sheet 7