MASTER CONTROL PANEL REPAIR - Continued
MASTER CONTROL PANEL REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  102    103    104    105    106  107  108    109    110    111    112  
img
.
TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 68 of 73)
Master Control Panel Wiring Harness Replacement (Sheet 5 of 7)
INSTALLATION
1.
Position connector (A) onto panel.
2.
Using flat-tip screwdriver on screws (B)
and 11/32 inch wrench on nuts (D), install
four screws (B), lockwashers (C), and
nuts (D) to secure connector (A) to panel
(E).
3.
Using socket, install two lockwashers
(F), flatwashers (G), and nuts (H)
securing two harness junctions (J) to
panel.
4.
Apply silicone compoud to all male
electrical connectors of wiring harness
(K).
Go on to Sheet 6
TA168756
10-105