TM 5-5420-226-20-3
DUST DETECTOR OPERATIONAL TEST(Sheet 1 of 3)
TOOLS:
1/2 in. combination box and open end wrench
SPECIAL TOOLS: Ground hop kit (Item 30, Chapter 3, Section I) if powerplant is out of tank
NOTE
Operational test may be performed with
powerplant out
of vehicle if ground kit has starter
cable modified
to accommodate improved clean
air system. If
ground hop kit
according to procedures on page 5-27.
Operational test is the same for both right and left
sides.
1.
Remove dust and dirt from filter strip cover (A) and compressor housing (B).
Using wrench, remove three screws (C) securing filter strip cover (A) to compressor
2.
housing (B), but do not remove cover (A).
Insert l-inch wide strip of nonporous material (plastic, celluloid, etc.) over filter strip (D).
3.
Using wrench, tighten three screws (C).
4.