TM 5-5420-226-20-3
BRAKE QUICK-DISCONNECT AND HOSE ASSEMBLY REPLACEMENT (Sheet 4 of 7)
CLEANING AND INSPECTION:
WARNING
To prevent personal injury, wear
Dry cleaning solvent P-D-680 is toxic and flammable.
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
1.
Clean all metallic parts with dry cleaning solvent.
2.
Inspect all parts for damage or wear. Replace all unserviceable parts.
3.
Inspect tube and hose assembly nuts for cracks. Replace tube or hose assembly if cracks
are found.
INSTALLATION:
1.
Insert coupling half (A) through hole
in bracket (B).
2.
Thread nut (C) onto coupling half (A)
finger tight.
Using 13/16 inch wrench to hold coupling
3.
(A) and 7/8 inch wrench on nut (C),
tighten nut.
4.
Thread tee (D) on coupling half
(A) finger tight.
NOTE
Do not tighten nut of tee (D) at this
time. It will have to be alined later.
Go on to Sheet 5