TM 5-5420-227-24
PERISCOPE MOUNT LID LATCH REPAIR (Sheet 1 of 2)
7/16 in. socket with 1/2 in. drive
TOOLS:
5 in. extension with 1/2 in. drive
SUPPLIES:
REFERENCE:
Close driver's hatch (TM 5-5420-226-1 O)
PRELIMINARY PROCEDURE:
DISASSEMBLY:
Using socket and extension, loosen two screws
1.
(A) on underside of mount (B) at latch (C).
Supporting latch (C) with one hand, remove two screws (A)
2.
3.
Lower latch (C) from mount (B) together with latch spring
(E) and shim (F).
With latch (C) removed from mount (B), separate latch from shim
4.
(F) and remove spring (E).
TA170253
Go on to Sheet 2
3-25