TM 5-5420-227-24
PERISCOPE MOUNT LID ASSEMBLY REPAIR (Sheet 1 of 3)
Vise
1/2 in. portable electric drill
TOOLS:
3/8 in. drill bit
Welding equipment
Cross-tip screwdriver
Electric grinder
Water
SUPPLIES:
Lockwashers (2 required)
PRELIMINARY PROCEDURE:
DISASSEMBLY:
1.
Using screwdriver, remove two screws (A), lockwashers (B), and strap (C) from lid (D).
Pull lightly on loop of spring (E) to release loop from handle (F).
2.
Slide handle out of spring (E) and retainer of lid (D).
3.
Remove spring (E) from lid (D).
4.
5.
Place lid (D) in vise and using drill with drill
bit, remove two bearings (G) (5/8 inch deep).
6.
Using grinder, remove weldments from metal tongs
holding bumper (H) to lid.
7.
Remove bumper (H).
Go on to Sheet 2
TA170258
3-30