TM 5-5420-227-24
PERISCOPE MOUNT RETAINER REPAIR (Sheet 2 of 3)
3.
Using screwdriver, remove four shoulder screws (E).
4.
Remove four retainers (F) together with two extension
springs (G) from mount (C).
CLEANING AND INSPECTION:
1.
Visually inspect all parts for damage or wear. All damaged or worn parts must be
replaced.
2.
Visually inspect parts for corrosion. All corroded parts which cannot be cleaned with
crocus cloth or steel wool must be replaced.
Go on to Sheet 3
TA170256
3-28