TM 5-5420-228-24
SMOKE GRENADE DISCHARGER WIRING HARNESS ASSEMBLY REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
WARNING
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
Connect electrical connector (A)
1.
of harness (B) to headlight adapter
receptacle (C). Connect electrical
connector (D) to discharger unit recep-
tacle (E).
Put clamp (F) on harness (B).
2.
Using socket and ratchet, install and
3.
tight-en screw (G) and lockwasher (H)
to secure clamp (F) and harness (B)
to headlamp guard (J).
Per form smoke grenade launcher
4.
functional check (TM 5-5420-202-20).
End of Task
TA251745
4-97