TM 5-5420-278-10
0060 00
0060 00-3/4 blank
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Unit Hydraulic Troubleshooting (Contd)
5. BAP WINCH ASSEMBLY WILL NOT LIFT LOAD OR OPERATES SLOWLY
NOTE
Perform the following check by operating
CBT/winch with a load in place.
Step 1. With load attached to hook on winch cable, set BAP winch switch on
remote control unit to IN position.
If cable will not lift load or operates slowly, perform step 2.
Step 2. Check for any binding or obstruction to winch cable and/or loose or
missing mounting hardware.
Step 3. Check fluid level in BAP winch.
If fluid level is low, notify unit maintenance.
Step 4. Check for leaks in the BAP or for other obvious damage to winch
lines and fittings.
a. If leaks are found, notify unit maintenance.
b. If no leaks or damage is found, perform step 5.
Step 5. Check if BAP winch quick-disconnect connectors are properly
connected to CBT fluid system quick-disconnect connectors.
a. Disconnect and reconnect quick-disconnect connectors.
b. If winch still does not operate properly, perform step 6.
Step 6. Check remote control unit using receptacle on opposite side of
transporter.
a. If winch operates, complete mission and notify unit maintenance
about remote control receptacle that does not work.
b. If winch does not operate, notify unit maintenance.
END OF TESTING
END OF WORK PACKAGE