TM 5-5420-278-24&P0032 000032 00-2DRAINING AND FILLING PUMP SYSTEM (Contd)NOTEDraining and filling of fluids are the same for both pumps andcylinders. Right side pump and cylinder are shown.PUMPWARNINGAccidental or intentional introduction of liquid contaminants intothe environment is in violation of state, federal, and militaryregulation. Refer to Army POL (WP 0001 00) for informationconcerning storage, use, and disposal of these liquids. Failure todo so may result in injury or death.CAUTIONCap or plug all hoses, fittings, and openings immediately afterdisconnecting to prevent contamination. Remove caps or plugsprior to installation. Failure to do so may result in damage toequipment.NOTETag hoses for installation.Have clean container ready to catch fluid.1.Open access cover (3) on inner ponton (1).WARNINGRelieve residual pressure on fluid system before disconnectinglines by moving control valve lever to all positions and thenplacing lever in transport/crossing position. Failure to do so mayresult in injury or death.2.Disconnect hose assemblies (7), (8), and (9) from quick-disconnect couplings (6), (5), and (10).3.Place control lever (12) to DOWN position (13) on pump (11), install handle (2) on lever (4), andoperate handle (2) until yoke (17) is fully retracted.56789103214YELLOWREDNEUTRAL