TM 5-5420-278-24&P
0032 00
0032 00-2
DRAINING AND FILLING PUMP SYSTEM (Contd)
NOTE
Draining and filling of fluids are the same for both pumps and
cylinders. Right side pump and cylinder are shown.
PUMP
WARNING
Accidental or intentional introduction of liquid contaminants into
the environment is in violation of state, federal, and military
regulation. Refer to Army POL (WP 0001 00) for information
concerning storage, use, and disposal of these liquids. Failure to
do so may result in injury or death.
CAUTION
Cap or plug all hoses, fittings, and openings immediately after
disconnecting to prevent contamination. Remove caps or plugs
prior to installation. Failure to do so may result in damage to
equipment.
NOTE
Tag hoses for installation.
Have clean container ready to catch fluid.
1.
Open access cover (3) on inner ponton (1).
WARNING
Relieve residual pressure on fluid system before disconnecting
lines by moving control valve lever to all positions and then
placing lever in transport/crossing position. Failure to do so may
result in injury or death.
2.
Disconnect hose assemblies (7), (8), and (9) from quick-disconnect couplings (6), (5), and (10).
3.
Place control lever (12) to DOWN position (13) on pump (11), install handle (2) on lever (4), and
operate handle (2) until yoke (17) is fully retracted.
5
6
7
8
9
10
3
2
1
4
YELLOW
RED
NEUTRAL