TM 5-5420-278-24&P
0032 00
0032 00-4
DRAINING AND FILLING PUMP SYSTEM (Contd)
PUMP (Contd)
6.
Operate pump handle (1) until pump reservoir (2) is empty.
7.
Place control lever (3) to TRANSPORT/CROSSING position (4).
NOTE
Perform steps 8, 9, 10, and 11 if pump is not being removed or
after pump is installed.
8.
Remove filler cap with dipstick (5) and gasket (7) from pump reservoir (6). Discard O-ring seal (7) if
damaged.
9.
Install funnel on pump reservoir (6), fill reservoir (6) with fluid, and check fluid level. Fluid level
must be between the min. and max. mark on filler cap dipstick (8) when dipstick (8) is placed on
top of pump reservoir opening (9). Do not thread filler cap on reservoir (6) when checking fluid.
10.
Install filler cap with dipstick (5) on pump reservoir (6).
11.
Remove hose (12) and quick-connector (11) from quick-disconnect coupling (13) on inner ponton (10)
if cylinder fluid is not being changed.
1
2
3
4