TM 5-5420-278-24&P
0035 00
0035 00-2
PUMP MAINTENANCE (Contd)
NOTE
Removal and installation of pumps are the same. Right side
is shown.
REMOVAL
WARNING
Accidental or intentional introduction of liquid contaminants into
the environment is in violation of state, federal, and military
regulation. refer to Army POL (WP 0001 00) for information
concerning storage, use and disposal of these liquids. Failure to do
so may result in injury or death
CAUTION
Cap or plug all hoses, connections, and openings immediately
after disconnection to prevent contamination. Remove caps or
plugs prior to installation. Failure to do so may result in damage
to equipment.
NOTE
Fluid system must be bled whenever pumps, cylinders, or hoses
are replaced.
Tag all hoses for installation.
Have container ready to catch oil.
WARNING
Relieve residual pressure on fluid system before disconnecting
lines by moving control valve lever to all positions and then
placing lever in transport/crossing position. Failure to do so may
result in injury or death.
1.
Remove hose assembly (9) and O-ring (3) from adapter (8) on pump reservoir access cover (7).
Discard O-ring (3).
2.
Remove hose assembly (4) and O-ring (3) from adapter (2) on pump housing (16). Discard
O-ring (3).
3.
Remove hose assembly (14) and O-ring (3) from adapter (15) on pump housing (16). Discard
O-ring (3).
4.
Remove four nuts (12), lockwashers (13), washers (6), screws (5), and pump (1) from two support
brackets (11) on inner ponton (10). Discard lockwashers (13).
5.
Remove adapters (2) and (15) from pump housing (16).
6.
Remove adapter (8) from pump reservoir access cover (7).