TM 5-5420-278-24&P
0035 00
0035 00-8
PUMP MAINTENANCE (Contd)
INSTALLATION
1.
Apply sealant to male threads of adapters (2), (8), and (15).
2.
Install adapter (8) on pump reservoir access cover (7).
3.
Install adapters (2) and (15) on pump housing (16).
4.
Install pump (1) on two support brackets (11) on inner ponton (10) with four washers (6),
screws (5), new lockwashers (13), and nuts (12).
5.
Apply fluid to three new O-rings (3) and install O-rings (3) on hose assemblies (4), (9), and (14).
6.
Connect hose assembly (14) with O-ring (3) to adapter (15) on pump housing (16).
7.
Connect hose assembly (4) with O-ring (3) to adapter (2) on pump housing (16).
8.
Connect hose assembly (9) with O-ring (3) to adapter (8) on pump reservoir access cover (7).
9.
Fill pump reservoir system (WP 0032 00).
10.
Fold and connect pontons, if separated (WP 0023 00).
11.
Bleed fluid system (WP 0038 00).
12.
Install ramp bay on transporter (TM 5-5420-278-10).