TM 5-5420-280-23&P
0008 00
Electrical System Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
36. RCU WILL NOT LOWER LAUNCH BOOM TO PRE-COUPLING POSITION (R9-A)
Step 1. Check that KY1 and KY16 hydraulic control valve solenoid LED lights are lit when action
button 2 is depressed.
NOTE
Potentiometer JR2 is used to stop launch boom at a set position in
the retrieval procedure.
a. If both lights are lit on control valve solenoids, check potentiometer JR2 position 7 to see
if damaged or out of adjustment. Adjust or replace potentiometer JR2. Refer to
b. If potentiometer JR2 is operating and control valve solenoid lights are lit, refer to
c. Check operation of IQAN-XP and IQAN-XS LED lights. Refer to WP 0004 00 step h.
Step 2. Check to see if one or more control valve solenoid LED lights are out when action button 2
is depressed.
a. If light is out, check for 24 volts at control valve solenoid.
b. If connector has 24 volts, replace control valve solenoid or hydraulic control valve. Refer
c. If connector has no voltage, check wires at KL-1 buss bar pin 1 for KY1 control valve
solenoid, KL-1 buss bar pin 16 for KY16 control valve solenoid, and KL-1 buss bar
pins 34, 35, and 48 for JR2 potentiometer. Refer to Electrical System Schematic (WP 0122
d. Check wire between KL-1 buss bar pin 1 and IQAN-XS connector pins 20. Replace wire if
e. Check wire between KL-1 buss bar pins 16, 34, 35, and 48 and IQAN-XP connector
pins 35, 15, 17, and 1. Replace wire if damaged. Refer to WP 0053 00.
END OF TESTING
37. RCU WILL NOT RAISE SECONDARY BOOM (R14-H)
Step 1. Check that KY1 and KY14 hydraulic control valve solenoid LED lights are lit when action
button 2 is depressed.
NOTE
Limit switch KA6 stops secondary boom and starts launch boom to
lower
a. If all lights are lit on control valve solenoids, check limit switch KA6 to see if damaged or
out of adjustment. Adjust or replace limit switch KA6. Refer to WP 0056 00.
b. If limit switch KA6 is operating and control valve solenoid lights are lit, refer to
c. Check operation of IQAN-XP and IQAN-XS LED lights, refer to WP 0004 00 step h.