WINCH CONTROL VALVES AND SOLENOIDS REPLACEMENT
WINCH CONTROL BLOCK AND ADAPTER PLATE REPLACEMENT

Special Tools List For Rapidly Emplaced Bridge (Reb) Page Navigation
  365    366    367    368    369  370  371    372    373    374    375  
img
TM 5-5420-280-23&P
0062 00
WINCH CONTROL VALVES AND SOLENOIDS REPLACEMENT (Contd)
REMOVAL
1. Loosen screw (8), disconnect electrical connector (7) from solenoid (5), and remove seal (6).
2. Remove nut (4), solenoid (5), and O-ring (9) from shaft (10) on control block (11). Discard O-ring (9).
NOTE
All control valves are replaced the same way. Only one control valve
is shown.
Have container ready to catch oil.
3. Loosen screw (1), disconnect electrical connector (2) from solenoid (14) on control valve (13), and
remove seal (15).
4. Remove four screws (3), control valve (13), and O-rings (12) from control block (11). Discard
O-rings (12).
INSTALLATION
NOTE
Apply a light coat of hydraulic oil to O-rings at installation.
1. Install new O-rings (12) and control valve (13) on control block (11) with four screws (3).
2. Install seal (15) and electrical connector (2) on solenoid (14) and tighten screw (1).
NOTE
Apply a light coat of hydraulic oil to O-ring at installation.
Perform steps 3 and 4 if installing solenoid only on control block.
3. Install new O-ring (9) and solenoid (5) on shaft (10) of control block (11) with nut (4).
4. Install seal (6) and electrical connector (7) on solenoid (5) and tighten screw (8).
1
2
3
4
15
11
14
13
12
5
6
7
9
8
10
END OF WORK PACKAGE