WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT
WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT - Continued

Special Tools List For Rapidly Emplaced Bridge (Reb) Page Navigation
  374    375    376    377    378  379  380    381    382    383    384  
img
TM 5-5420-280-23&P
0065 00
WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT (Contd)
REMOVAL
NOTE
Tag all electrical leads for installation.
1. Slide connector lock (13) down, and disconnect winch electrical harness connector EX-1 (14) from
electronic box receptacle (12) on electronic box (6).
2. Loosen screw (11), and disconnect electromagnet motor connector EX-6 (10) from shift valve solenoid
receptacle (9).
3. Disconnect force transmitter connector EX-17 (8) from force transmitter receptacle (7).
4. Remove nut (16), washer (1), star washer (15), ground cables (2) and (3), and washer (4) from ground
stud (5) on winch electronics box (6).
1
3
5
2
6
4
16
15
14
13
12
7
8
11
9
10