TM 5-5420-280-23&P
0065 00
WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT (Contd)
REMOVAL
NOTE
Tag all electrical leads for installation.
1. Slide connector lock (13) down, and disconnect winch electrical harness connector EX-1 (14) from
electronic box receptacle (12) on electronic box (6).
2. Loosen screw (11), and disconnect electromagnet motor connector EX-6 (10) from shift valve solenoid
receptacle (9).
3. Disconnect force transmitter connector EX-17 (8) from force transmitter receptacle (7).
4. Remove nut (16), washer (1), star washer (15), ground cables (2) and (3), and washer (4) from ground
stud (5) on winch electronics box (6).
1
3
5
2
6
4
16
15
14
13
12
7
8
11
9
10
Change 1