WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT - Continued
WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT - Continued

Special Tools List For Rapidly Emplaced Bridge (Reb) Page Navigation
  376    377    378    379    380  381  382    383    384    385    386  
img
TM 5-5420-280-23&P
0065 00
WINCH ELECTRICAL HARNESS AND GROUND CABLE REPLACEMENT (Contd)
REMOVAL (Contd)
8. Disconnect rope loop sensor connector EX-13 (5) from rope loop monitoring sensor (1).
9. Disconnect pressure sensor connector EX-8 (4) from pressure sensor (2). Remove and discard tie-
down straps (3) where necessary.
1
5
4
2
3
10. Disconnect power cable connector EX-5 (12) from receptacle (11) on winch electrical harness cable
EX-2 (10).
11. Disconnect control cable connector WINDE (6) from receptacle (7) on winch electrical harness cable
EX-75 (8). Remove and discard tie-down straps (9) where necessary.
Change 1
0065 00-4