TM 5-5420-280-23&P
0108 00
ENGINE OIL BATH AIR CLEANER AND ADAPTER FLANGES MAINTENANCE (Contd)
REMOVAL
1.
Support air cleaner base (12) and unlock two clips (13) from base (12) and air cleaner housing (10).
2.
Remove base (12) and O-ring seal (11) from housing (10). Discard O-ring seal (11).
3.
Loosen screw (15) and remove dust cap (14) from inlet tube (16) on housing (10).
4.
Remove four screws (3), lockwashers (4), housing (10), and gasket (5) from adapter flange (1) and
mounting bracket (8). Discard lockwashers (4) and gasket (5).
5.
Loosen two clamps (2) on hose (7) and two adapter flanges (1).
6.
Remove four screws (3), lockwashers (4), adapter flange (1), and gasket (5) from intake manifold (6).
7.
Remove two adapter flanges (1), clamps (2), hose (7), and gasket (5) from between mounting bracket
(8) and intake manifold (6). Discard gasket (5).
CLEANING AND INSPECTION
WARNING
Cleaning solvent mixture is combustible. Use mechanical
ventilation whenever product is used in a confined space, is heated
above ambient temperatures, or is agitated. DO NOT use or store
near heat, sparks, flame, or other ignition sources. Keep container
sealed when not in use.
Contact with cleaning solvent may cause skin irritation. Use
chemical-resistant gloves. In case of skin contact, remove any
contaminated clothing and wash skin thoroughly with soap and
water. wash contaminated clothing before reuse. Eye contact may
cause irritation, tearing, or blurring of vision. Use face shield or
goggles when eye contact may occur. In case of eye contact, flush
eyes with large amounts of water for at least fifteen (15) minutes or
until irritation subsides. Inhalation may cause irritation to upper
respiratory passages. DO NOT have food or drink in the vicinity.
Failure to comply may result in injury to personnel.
1.
Clean all parts with cleaning solvent and dry with cloth before inspection.
2.
Inspect filter packing (17) for uneven sealing surface. Replace if uneven.
3.
Inspect filter packing (17) for missing filter wool. Replace if wool is missing.
4.
Inspect filter housing (10) for cracks. Replace if cracked.
5.
Inspect weld nuts (9) for damaged or worn threads. Replace if damaged or worn.
INSTALLATION
1.
Install two clamps (2), hose (7), two new gaskets (5), and adapter flanges (1) between intake
manifold (6) and mounting bracket (8).
2.
Align holes in adapter flange (1), gasket (5), and intake manifold (6) and install four new
lockwashers (4) and screws (3).
3.
Position new gasket (5) and housing (10) on mounting bracket (8), align holes in two gaskets (5),
mounting bracket (8), and weld nuts (9) on housing (10), and install four new lockwashers (4) and
screws (3).
4.
Tighten two clamps (2).
Change 1