TM 55-1945-205-10-2
0114 00 29
0114 00
WARNING
Use approved procedures when cleaning up fuel spills. Take proper precautions
when removing or installing any fuel system component. Failure to comply may
result in serious injury to death to personnel.
2
After
.2
Light Tower Engine 1. Check for leaks around fuel tank
and fuel lines. If any leaks are
found, contact unit maintenance.
Any Class I fuel
leakage is found.
a. Examine fuel lines and flexible
hoses for leaks. Check that
fittings, clamps and ties are
secure. If lines or hoses are
leaking or fittings, clamps or ties
are not secure, contact unit
maintenance.
Any Class I fuel
leakage
is found.
WARNING
b. Verify fuel tank is full by
checking indicator gauge or
using a fuel stick. If necessary,
add fuel. DO NOT OVER FILL.
Service with Diesel, Fuel
W-F-800 Grade DF-2 from
-25°F to +150°F. Tank capacity
is 30 gallons (114 liters). Fill
to 95%.
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/