TM 55-1945-205-10-2
0114 00 47
0114 00
4
Quarterly
.5
Personnel Shelter
(Contd)
2. Clean incinerator toilet interior of
dust and paper bits.
(TM 55-1925-257-14&P)
WARNING
3. Grease all moving parts of the
incinerator toilet flushing assembly
and foot pedal.
(TM 55-1925-257-14&P)
4. Clean the blower assembly,
blower housing and vent line elbow.
(TM 55-1925-257-14&P)
WARNING
5
Quarterly
.5
EASY
Lubricate EASY door hinges.
Lubricate with grease, MIL-G-
81322. Grease by hand.
3
Annually
2.5
Generator Container Inspect fire suppression system in
accordance with 46 CFR Parts
91.25-20 and 97.15-60. Contact
Specialized repair Activity (SRA).
Fire suppression
system is
inoperative.
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
GAA
GAA