TM 55-1945-205-10-40099 00 40099 001 Before .1 Light Tower (Cont’d) 4. Check for flat or dry rotted tires.Check tire inflation with tirepressure gage. Tires should beinflated to 32 PSI. If tires are flat ordry rotted, contact unit maintenance.5. Check the electrical controlcompartment for damaged orburned wiring. If wiring is damagedor burned, contact unit maintenance.6. Check for damaged or fadedwarning and caution decals. decalsare damaged or faded, contact unitmaintenance.7. Clear the air ventsof obstructions.8. Check acoustic material on lightset enclosure panels for damage ormissing material. If panels aredamaged or missing, contact unitmaintenance.9. Check for evidence of arcing onelectrical terminals. If arcing isfound, contact unit maintenance.10. Inspect electrical wiring toensure that it is securely connected,clean and undamaged. If wiring isnot securely connected, dirty ordamaged, contact unit maintenance.Table 1. Preventive Maintenance Checks and Services. (Continued)ITEMNO.INTERVALMAN-HOURSITEM TO BECHECKED ORSERVICEDPROCEDUREEQUIPMENTNOT READY/AVAILABLE IF:CABLEPULLEYCABLELOCKING PINWINCH