TM 55-1945-205-10-4
0099 00 5
0099 00
1
Before
.1
Light Tower (Contd) 11. Check all accessible fuse
terminal blocks and connections to
see that they are securely connected
and supported, that insulation is not
cracked or chafed and that conduit
and shielding are secure and in
good condition. If terminal blocks
are not securely connected or
supported, insulation is cracked or
chafed or shielding is damaged,
contact unit maintenance.
WARNING
2
Before
.4
Light Tower Engine 1. Check the engine oil level.
a. Verify that it registers FULL
on the dipstick. Engine must be
cool when reading level. If hot,
allow to cool for 20 minutes. If
necessary, add Lubricating Oil,
Internal Combustion Engine,
Grade 15W40 to achieve desired
level. DO NOT OVERFILL.
Use a rag to wipe any spillage
that may occur.
b. Make a visual inspection for
oil leaks around the filters and
the external oil lines. If oil leaks
are found, contact unit
maintenance.
Class III oil leaks
are found.
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
1. OIL LEVEL GAUGE
1
A
A: ENGINE OIL LEVEL WITHIN
THIS RANGE IS PROPER