TM 55-1945-205-10-40099 00 500099 0018 Monthly 1.0 Flexors 1. Inspect uninstalled flexors forseparation of the polyurethanematerial in the center. If found,contact unit maintenance.Separation of thepolyurethanematerial in thecenter of the flexoris found.2. Inspect uninstalled flexors forcracks in the external welds on theends. If found, contact unitmaintenance.Cracks arediscovered in theexternal weldmentson the ends of theflexor.20 Monthly .5 Lifting Slings Check lifting slings for cuts, loosestitching and fraying. If cuts, frayingor loose stitching is found, contactunit maintenance.21 Monthly 5.0 Module InterlockConnector (MaleLocking Pin)1. Check male connector pin fordeformation, twisting, bending andflatness. If any deformation of thepin is present, remove pin fromservice. Contact unit maintenance.Any deformation ofthe pin is present.2. Check contact area where the pinsseat against the guillotine bars forwear. If excessive wear is present,remove pin from service. Contactunit maintenance.Excessive wear ispresent.Table 1. Preventive Maintenance Checks and Services. (Continued)ITEMNO.INTERVALMAN-HOURSITEM TO BECHECKED ORSERVICEDPROCEDUREEQUIPMENTNOT READY/AVAILABLE IF:POLYURETHANE SECTIONMETAL ENDMETAL END