TM 55-1945-205-10-4
0099 00 50
0099 00
18
Monthly
1.0
Flexors
1. Inspect uninstalled flexors for
separation of the polyurethane
material in the center. If found,
contact unit maintenance.
Separation of the
polyurethane
material in the
center of the flexor
is found.
2. Inspect uninstalled flexors for
cracks in the external welds on the
ends. If found, contact unit
maintenance.
Cracks are
discovered in the
external weldments
on the ends of the
flexor.
20
Monthly
.5
Lifting Slings
Check lifting slings for cuts, loose
stitching and fraying. If cuts, fraying
or loose stitching is found, contact
unit maintenance.
21
Monthly
5.0
Module Interlock
Connector (Male
Locking Pin)
1. Check male connector pin for
deformation, twisting, bending and
flatness. If any deformation of the
pin is present, remove pin from
service. Contact unit maintenance.
Any deformation of
the pin is present.
2. Check contact area where the pins
seat against the guillotine bars for
wear. If excessive wear is present,
remove pin from service. Contact
unit maintenance.
Excessive wear is
present.