TM 55-1945-205-10-4
0006 00 2
0006 00
rating of 37 dB and a frequency stability (-20 ° to +50 ° C) of + 0.0005%. The receiver has a sensitivity rating of
20 dB, quieting at 0.35 uv and 12 dB SINAD at 0.30 uv. The squelch sensitivity (threshold) is 0.20 uv. Modulation
acceptance bandwidth is + 4.5 khz.
INCINERATOR TOILET
Refer to TM 55-1925-257-14&P for the theory of operation of the incinerator toilet.
FLOATING CAUSEWAY ANCHOR MOORING SYSTEM (FCAMS)
The FCAMS is designed to hold the floating causeway during logistics over the shore (LOTS) operations in sea
conditions up to Sea State 3. The offshore mooring leg is designed to perform in soft soils and sand. The onshore
mooring leg is designed to perform in soft soils, sand and competent rock. In addition to Sea State, the capability of
the FCAMS to hold the floating causeway in position is highly dependent on the alongshore current speed and
number and type of vessels mooring to the floating causeway. It is also dependent on the water depth at the vessels
location. The complete system, which has 16 offshore mooring legs and four onshore mooring legs, is required for a
full floating causeway that is 1500 ft long.