TM 55-1945-205-10-4
0007 00 2
0007 00
Table 1. Light Tower Operator Controls and Indicators.
KEY
CONTROL/INDICATOR
FUNCTION
1
HOUR METER
Indicates elapsed time in hours that the light tower engine
has operated.
2
FUEL LEVEL
Indicates the fuel level in the light tower fuel tank.
3
Ignition Switch
Allows the operator to select between preheat, run, start and off.
The PREHEAT position preheats the glow plugs to aid starting.
The START position allows for starting of the engine. The
ignition switch is spring loaded to the RUN position when the
key is released after starting. The OFF position allows the
operator to turn the light tower engine off after use.
4
MAIN BREAKER
Allows the operator to turn off all electrical power to the lights
and receptacles. The main breaker is rated at 35 amps.
5
LAMP 1
Circuit breaker switch allows the operator to turn on and off
lamp number one on the light tower.
6
LAMP 2
Circuit breaker switch allows the operator to turn on and off
lamp number two on the light tower.
7
LAMP 3
Circuit breaker switch allows the operator to turn on and off
lamp number three on the light tower.
8
LAMP 4
Circuit breaker switch allows the operator to turn on and off
lamp number four on the light tower.
9
PUSH TO RESET
Circuit breaker for light power circuit.
10
RECEPTACLE, 120 V 20A
120 volt, 20 amp electrical receptacle.
11
RECEPTACLE, 240 V 20A
240 volt, 20 amp electrical receptacle.
12
Locking Pin
Secures light tower in upright position.
13
Locking Pin
Locks light tower in the stowed position for transport.
14
Eye Bolt
Allows light tower to rotate. Prevents rotation when tightened.
15
Locking Pin
Locks light tower in position for angled operation.
16
Winch
Raises light tower when turned from the stowed position.
Returns light tower to stowed position after operation.
17
Winch
Extends light tower to desired height.
18
Speed Control Lever
Controls engine speed during operation.
19
Engine Stop Lever
Allows operator to stop engine without returning to
control panel.
