TM 55-1945-205-24-20029 00 20029 00MALFUNCTIONThermostat contacts are open.CORRECTIVE ACTIONAdjust thermostat to close contacts or replace thermostat as required. (WP 0107 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-2)MALFUNCTIONSelector switch is defective. CORRECTIVE ACTIONReplace selector switch. Contact depot maintenance.MALFUNCTIONCompressor system wiring is defective.CORRECTIVE ACTIONUsing multimeter, check continuity of wiring to compressor. If continuity is not present, repair/replace wiring as necessary. (WP 0348 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-2)MALFUNCTIONSystem overload protector is open or defective.CORRECTIVE ACTIONTest the overload protector. (WP 0110 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-2)MALFUNCTIONThe fan motor is defective.CORRECTIVE ACTIONReplace fan motor. (WP 0108 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-2)END OF WORK PACKAGE